{"id":31155,"date":"2026-10-15T08:46:46","date_gmt":"2026-10-15T08:46:46","guid":{"rendered":"https:\/\/doingcable.com\/?p=31155"},"modified":"2026-10-15T08:46:48","modified_gmt":"2026-10-15T08:46:48","slug":"what-is-copper-tape-used-for-2","status":"publish","type":"post","link":"https:\/\/doingcable.com\/ar\/what-is-copper-tape-used-for-2\/","title":{"rendered":"What is Copper Tape used for?"},"content":{"rendered":"<p><strong><a href=\"https:\/\/doingcable.com\/ar\/\">Copper tape<\/a><\/strong> is a precision-slit, soft-annealed electrolytic tough pitch (ETP) copper foil used as a metallic screen in power, control, instrumentation, and data cables. It provides near-100 % conductive coverage to equalise the electric field, drain capacitive and fault currents, suppress EMI\/RFI, and improve overall electromagnetic compatibility.<\/p>\n\n\n\n<p>In medium-voltage XLPE cables rated 6\u201335 kV, the tape is helically applied over the extruded semi-conducting insulation screen. In control and instrumentation cables it is applied over the core assembly (or individual pairs) to reduce crosstalk and external interference. Typical commercial grades are \u226599.9 % pure copper with conductivity of 98\u2013100 % IACS in the soft (O) temper.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/doingcable.com\/ar\/product\/\u0634\u0627\u0631\u0639-\u0627\u0644\u0646\u062d\u0627\u0633\/\">\u0627\u0633\u062a\u0639\u0644\u0645 \u0627\u0644\u0622\u0646<\/a><\/div>\n<\/div>\n\n\n\n<p>What is a Copper Tape Shield? MV-105 Cable Technical Guide Article<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1077\" height=\"682\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable.png\" alt=\"\" class=\"wp-image-31156\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable.png 1077w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-400x253.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-768x486.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-18x12.png 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-430x272.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-700x443.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/600V-1kV-Copper-Tape-Shielded-VFD-Cable-doingcable-250x158.png 250w\" sizes=\"(max-width: 1077px) 100vw, 1077px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">What Is the Primary Function of Copper Tape in Cable Construction?<\/h3>\n\n\n\n<p>Copper tape forms a continuous low-resistance metallic barrier that confines the electric field within the insulation, provides a path for charging and short-circuit currents, and attenuates high-frequency interference. In MV cables the helical wrap with controlled overlap creates a Faraday-cage effect that prevents partial discharge by eliminating field concentrations at the insulation surface.<\/p>\n\n\n\n<p>Standard practice uses 0.08\u20130.15 mm thick soft copper tape applied with 15\u201325 % overlap. This construction meets the requirements of IEC 60502 series (where national standards define the exact screen cross-section) and common Chinese practice under GB\/T 12706 (minimum average overlap 15 % of tape width, single-core thickness \u22650.12 mm, multi-core average \u22650.10 mm).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1280\" height=\"720\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1.jpg\" alt=\"\" class=\"wp-image-31158\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1.jpg 1280w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-400x225.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-768x432.jpg 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-18x10.jpg 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-430x242.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-700x394.jpg 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable1-250x141.jpg 250w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">How Does Copper Tape Compare with Copper Wire Screen?<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th><th>Copper Tape Screen<\/th><th>Copper Wire Screen<\/th><\/tr><\/thead><tbody><tr><td>Coverage<\/td><td>Near 100 %<\/td><td>80\u201395 % (braid density dependent)<\/td><\/tr><tr><td>High-frequency EMI<\/td><td>\u0645\u0645\u062a\u0627\u0632<\/td><td>\u0645\u0639\u062a\u062f\u0644<\/td><\/tr><tr><td>Low-frequency \/ fault current<\/td><td>Moderate (limited by thin cross-section)<\/td><td>High (customisable 16\u201350 mm\u00b2)<\/td><\/tr><tr><td>\u0645\u0631\u0648\u0646\u0629<\/td><td>Good for fixed installation<\/td><td>Better for frequent bending<\/td><\/tr><tr><td>Typical thickness \/ size<\/td><td>0.05\u20130.15 mm (5\u20136 mil common)<\/td><td>0.5\u20131.5 mm wires or braid<\/td><\/tr><tr><td>\u064a\u0643\u0644\u0641<\/td><td>\u0623\u062f\u0646\u0649<\/td><td>\u0623\u0639\u0644\u0649<\/td><\/tr><tr><td>Preferred application<\/td><td>Fixed MV power, instrumentation, data<\/td><td>High-fault systems, mobile or flexible cables<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Copper tape is preferred when uniform field control and high-frequency shielding are critical and expected earth-fault current is limited (resistance-grounded or compensated networks). Copper wire screen is specified when short-circuit withstand must exceed approximately 4\u20136 kA for 1 s.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1300\" height=\"731\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-1300x731.webp\" alt=\"\" class=\"wp-image-31159\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-1300x731.webp 1300w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-400x225.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-768x432.webp 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-1536x864.webp 1536w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-2048x1152.webp 2048w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-18x10.webp 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-430x242.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-700x394.webp 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/What-is-Copper-Tape-used-for-doingcable-250x141.webp 250w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Typical Technical Parameters<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th><th>Typical Range<\/th><th>Notes<\/th><\/tr><\/thead><tbody><tr><td>\u0645\u0627\u062f\u0629<\/td><td>Soft annealed ETP copper (C11000 \/ T2)<\/td><td>\u226599.9 % Cu<\/td><\/tr><tr><td>\u0627\u0644\u0645\u0648\u0635\u0644\u064a\u0629<\/td><td>\u226598\u2013100 % IACS<\/td><td>Measured at 20 \u00b0C<\/td><\/tr><tr><td>Thickness<\/td><td>0.05\u20130.15 mm (0.08\u20130.12 mm common)<\/td><td>Up to 0.20 mm for higher fault rating<\/td><\/tr><tr><td>Width<\/td><td>10\u2013100 mm (custom)<\/td><td>Selected by cable diameter and overlap<\/td><\/tr><tr><td>\u062d\u0650\u062f\u0651\u0629<\/td><td>Soft (O)<\/td><td>Fully annealed for formability<\/td><\/tr><tr><td>Overlap<\/td><td>15\u201325 % (min. average 15 %)<\/td><td>Ensures continuity after bending<\/td><\/tr><tr><td>Application method<\/td><td>Helical or longitudinal<\/td><td>Helical preferred for MV field control<\/td><\/tr><tr><td>Surface<\/td><td>Clean, free of oxide, oil, and edge burrs<\/td><td>Critical for low contact resistance<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Tapes are supplied on paper or plastic cores (\u00d8150\u2013500 mm) in lengths suitable for high-speed taping lines.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"550\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable.webp\" alt=\"\" class=\"wp-image-31157\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable.webp 750w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable-400x293.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable-16x12.webp 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable-430x315.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable-700x513.webp 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/cable-shielding-doingcable-250x183.webp 250w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Main Application Areas<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medium-voltage XLPE power cables (6\/10 kV to 18\/30 kV) \u2014 helical copper tape screen over insulation screen for radial field control and charging-current drainage.<\/li>\n\n\n\n<li>Control and instrumentation cables (300\/500 V to 0.6\/1 kV) \u2014 collective or individual screening to reduce EMI and crosstalk in process plants and automation systems.<\/li>\n\n\n\n<li>Coaxial and data cables \u2014 outer conductor or supplemental screen for high-frequency signal integrity.<\/li>\n\n\n\n<li>Special cables (VFD, marine, mining) \u2014 combined with drain wires or used in multi-layer constructions.<\/li>\n<\/ul>\n\n\n\n<p>In resistively grounded industrial networks, standard 0.10\u20130.12 mm copper tape commonly provides approximately 4 kA \/ 1 s fault withstand. Higher fault levels require thicker tape, double-layer tape, or a hybrid tape-plus-wire design.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Standards and Compliance Reference<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IEC 60502-1 and IEC 60502-2: metal screen construction (tapes, wires or combination); exact cross-section defined by national practice.<\/li>\n\n\n\n<li>GB\/T 12706: copper tape average overlap \u226515 % of width; thickness \u22650.12 mm (single-core) \/ \u22650.10 mm (multi-core).<\/li>\n\n\n\n<li>ICEA \/ UL \/ CSA practices for North American MV-105 constructions: typically 5 mil (0.127 mm) copper tape with minimum 25 % overlap.<\/li>\n\n\n\n<li>Shielding performance evaluated by transfer impedance and shielding attenuation (IEC 62153 series methods).<\/li>\n<\/ul>\n\n\n\n<p>Proper grounding of the screen at terminations is mandatory; poor terminations are a frequent cause of elevated contact resistance and thermal damage under fault conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Selection and Process Considerations<\/h3>\n\n\n\n<p>Select thickness and width according to required short-circuit rating, cable diameter, and production line speed. Soft temper is essential; hard tape can cut into the semi-conducting screen or wrinkle during wrapping. Edge quality must be free of burrs to avoid stress points that initiate partial discharge. Tension and overlap are controlled on the taping head (typically 10\u201325 % overlap) to maintain electrical continuity after subsequent bending and installation.<\/p>\n\n\n\n<p>Longitudinal application is used for high-speed lines where uniform coverage and productivity are prioritised; helical application remains the standard for MV field-control screens.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Failure Modes and Prevention<\/h3>\n\n\n\n<p>Common issues include increased contact resistance caused by oxide growth at overlaps, tape cracking from excessive hardness or over-tension, and local field intensification from edge burrs or insufficient overlap. Prevention measures are: use fully annealed material, maintain clean surfaces, control overlap and tension, and specify point-welded joints rather than soldered or adhesive joints in critical MV constructions. After installation, screen continuity and resistance should be verified.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Points<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Copper tape delivers near-100 % coverage and superior high-frequency shielding compared with braid.<\/li>\n\n\n\n<li>Typical thickness 0.08\u20130.15 mm soft annealed ETP copper, 15\u201325 % helical overlap for MV cables.<\/li>\n\n\n\n<li>Preferred for fixed installations where field uniformity and EMI control dominate; wire screen preferred for high fault-current capacity.<\/li>\n\n\n\n<li>Complies with IEC 60502 and GB\/T 12706 practices when correctly dimensioned and applied.<\/li>\n\n\n\n<li>Reliable long-term performance depends on material purity, temper, edge quality, and controlled application.<\/li>\n<\/ul>\n\n\n\n<p>For custom widths, thicknesses, conductivity grades, or technical support on screen design and production-line compatibility, contact our engineering team.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Copper tape is a precision-slit, soft-annealed electrolytic tough pitch (ETP) copper foil used as a metallic screen in power, control,<\/p>","protected":false},"author":1,"featured_media":31160,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[565],"tags":[],"class_list":["post-31155","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized-en"],"_links":{"self":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/comments?post=31155"}],"version-history":[{"count":1,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31155\/revisions"}],"predecessor-version":[{"id":31161,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31155\/revisions\/31161"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media\/31160"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media?parent=31155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/categories?post=31155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/tags?post=31155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}