{"id":31162,"date":"2026-10-16T08:13:55","date_gmt":"2026-10-16T08:13:55","guid":{"rendered":"https:\/\/doingcable.com\/?p=31162"},"modified":"2026-10-16T08:30:04","modified_gmt":"2026-10-16T08:30:04","slug":"what-is-a-tubular-stranding-machine-2","status":"publish","type":"post","link":"https:\/\/doingcable.com\/ar\/what-is-a-tubular-stranding-machine-2\/","title":{"rendered":"What Is a Tubular Stranding Machine?"},"content":{"rendered":"<p>A <strong><a href=\"https:\/\/doingcable.com\/ar\/\">\u0622\u0644\u0629 \u062a\u062c\u062f\u064a\u0644 \u0623\u0646\u0628\u0648\u0628\u064a\u0629<\/a><\/strong> is a high-speed rotating-tube machine that assembles multiple bare or insulated wires into a concentric stranded conductor. The bobbins are mounted inside a long cylindrical tube that rotates as a single rigid body. This design delivers true 100 % back-twist, so each individual wire experiences almost no residual torsion while the finished conductor is formed.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/doingcable.com\/ar\/product\/\u0622\u0644\u0629-\u062a\u062c\u062f\u064a\u0644-\u0623\u0646\u0628\u0648\u0628\u064a\u0629\/\">\u0627\u0633\u062a\u0639\u0644\u0645 \u0627\u0644\u0622\u0646<\/a><\/div>\n<\/div>\n\n\n\n<p>Typical industrial configurations are 1+6, 1+12 and 1+18 (sometimes 1+24). Bobbin sizes range from PN400 to PN630 mm, with rotor speeds of 400\u20131 500 rpm and line speeds of 80\u2013230 m\/min depending on wire diameter and number of bays. The machine is the standard choice for producing IEC 60228 Class 2 circular and compacted copper and aluminium conductors used in power, control and overhead cables.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"479\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable.jpg\" alt=\"\" class=\"wp-image-31163\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable.jpg 640w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable-400x300.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable-16x12.jpg 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable-430x322.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable-250x187.jpg 250w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">How Does a Tubular Stranding Machine Work?<\/h3>\n\n\n\n<p>The entire tube rotates around its longitudinal axis while the central wire (or previously stranded core) travels straight through the centre. Outer wires are paid off from bobbins fixed inside the tube. Because the bobbins rotate with the tube but do not themselves rotate relative to the wire path, the wires leave the tube with zero net twist. A closing die or compacting rollers at the exit form the round or compacted strand. Lay length is set by the ratio of tube rotational speed to line speed and is controlled to within \u00b11 % by modern PLC systems.<\/p>\n\n\n\n<p>This 100 % back-twist geometry produces conductors with stable resistance, minimal residual stress and good flexibility\u2014properties required for Class 2 power cable conductors.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"638\" height=\"480\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2.jpg\" alt=\"\" class=\"wp-image-31164\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2.jpg 638w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2-400x300.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2-16x12.jpg 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2-430x324.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Tubular-Stranding-Closing-Line-doingcable2-250x188.jpg 250w\" sizes=\"(max-width: 638px) 100vw, 638px\" \/><\/figure>\n\n\n\n<p>Typical Technical Parameters<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th><th>Typical Range<\/th><th>Notes<\/th><\/tr><\/thead><tbody><tr><td>\u0625\u0639\u062f\u0627\u062f<\/td><td>1+6 \/ 1+12 \/ 1+18 (6B\u201318B, up to 24B)<\/td><td>Concentric Class 2 strands<\/td><\/tr><tr><td>Bobbin size<\/td><td>PN400 \/ PN500 \/ PN560 \/ PN630 mm<\/td><td>Larger bobbins reduce change-over time<\/td><\/tr><tr><td>Single-wire diameter<\/td><td>Cu 0.8\u20135.0 mm \/ Al 1.2\u20136.0 mm<\/td><td>Steel wire also possible<\/td><\/tr><tr><td>Finished conductor \u00d8<\/td><td>Up to 15\u201335 mm<\/td><td>Depends on wire count and compacting<\/td><\/tr><tr><td>Rotor speed<\/td><td>400\u20131 500 rpm<\/td><td>Higher for smaller bobbins<\/td><\/tr><tr><td>Line speed<\/td><td>80\u2013230 m\/min<\/td><td>100\u2013180 m\/min common on PN500\u2013630<\/td><\/tr><tr><td>Back-twist<\/td><td>100 %<\/td><td>Inherent to tubular design<\/td><\/tr><tr><td>Lay-length accuracy<\/td><td>\u2264 \u00b11 %<\/td><td>Encoder + servo control<\/td><\/tr><tr><td>Tension control<\/td><td>Magnetic-particle or hysteresis<\/td><td>Variance typically \u00b12 %<\/td><\/tr><tr><td>Take-up<\/td><td>PN1250\u2013PN2000<\/td><td>Shaft or portal type<\/td><\/tr><tr><td>Main motor power<\/td><td>45\u2013110 kW<\/td><td>Depends on size and speed<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2.avif\" alt=\"\" class=\"wp-image-31165\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2.avif 1000w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-400x300.avif 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-768x576.avif 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-16x12.avif 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-430x323.avif 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-700x525.avif 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable2-250x188.avif 250w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Where Are Tubular Stranding Machines Used?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medium- and low-voltage power cables: 7-wire and 19-wire Class 2 copper and aluminium conductors (IEC 60228).<\/li>\n\n\n\n<li>Overhead conductors: AAC, AAAC and the aluminium layers of ACSR.<\/li>\n\n\n\n<li>Control and instrumentation cables: small-section stranded cores.<\/li>\n\n\n\n<li>Steel wire rope and messenger wires when equipped for higher tensile materials.<\/li>\n\n\n\n<li>Compacted circular conductors for reduced outer diameter and improved current-carrying capacity.<\/li>\n<\/ul>\n\n\n\n<p>For conductors larger than approximately 70\u201395 mm\u00b2 or for sector-shaped cores, rigid-frame or planetary stranders are normally preferred because they can handle more wires and heavier bobbins.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3.avif\" alt=\"\" class=\"wp-image-31166\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3.avif 1000w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-400x300.avif 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-768x576.avif 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-16x12.avif 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-430x323.avif 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-700x525.avif 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/High-Speed-Tubular-Stranding-Machine-for-Copper-Aluminum-Steel-Wires-doingcable3-250x188.avif 250w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Selection Considerations<\/h3>\n\n\n\n<p>Choose bobbin size according to required production volume and wire diameter. PN500 and PN630 machines cover the majority of Class 2 power-cable work. Higher rotor speeds (and therefore higher line speeds) are achieved with smaller bobbins (PN400) and fewer bays. Full 100 % back-twist is the principal advantage over rigid-frame machines; it reduces residual torsion and improves conductor flexibility and dimensional stability.<\/p>\n\n\n\n<p>Modern machines include wire-break detection on every position, centralised lubrication, safety guarding with interlocks, and PLC\/HMI control that stores recipes for different constructions. Compacting dies or roller systems can be fitted at the closing point when compacted conductors are required.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1066\" height=\"800\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-1066x800.avif\" alt=\"\" class=\"wp-image-31167\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-1066x800.avif 1066w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-400x300.avif 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-768x576.avif 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-16x12.avif 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-430x323.avif 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-700x525.avif 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4-250x188.avif 250w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Cable-Manufacturing-Equipment-Steel-Wire-Tubular-Stranding-Machine-Strands-Twisted-Wire-Machinery-doingcable4.avif 1233w\" sizes=\"(max-width: 1066px) 100vw, 1066px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Standards Supported<\/h3>\n\n\n\n<p>Finished conductors produced on tubular stranders meet the requirements of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IEC 60228:2023 Class 2 (stranded circular and compacted conductors)<\/li>\n\n\n\n<li>ASTM B8 (concentric-lay stranded copper)<\/li>\n\n\n\n<li>IEC 61089 \/ ASTM B231 \/ B399 for aluminium overhead conductors<\/li>\n<\/ul>\n\n\n\n<p>Lay length, wire diameter uniformity and DC resistance are the primary parameters verified after stranding.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5.webp\" alt=\"\" class=\"wp-image-31168\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5.webp 800w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-400x300.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-768x576.webp 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-16x12.webp 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-430x323.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-700x525.webp 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/10\/Used-1-6-Tubular-Stranding-Machine-Overview-doingcable5-250x188.webp 250w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Key Points<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tubular stranders provide true 100 % back-twist with high rotational speeds (up to 1 500 rpm) and line speeds of 80\u2013230 m\/min.<\/li>\n\n\n\n<li>Standard configurations are 1+6, 1+12 and 1+18 with bobbins from PN400 to PN630 mm.<\/li>\n\n\n\n<li>Primary application is IEC 60228 Class 2 copper and aluminium conductors for power and overhead cables.<\/li>\n\n\n\n<li>Soft-annealed input wire, precise tension control and accurate lay length are essential for stable resistance and good compaction.<\/li>\n\n\n\n<li>For larger cross-sections or sector conductors, rigid or planetary machines are normally selected.<\/li>\n<\/ul>\n\n\n\n<p>Custom configurations, higher speeds, automatic bobbin loading and integrated compacting systems are available to match specific production requirements.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>A tubular stranding machine is a high-speed rotating-tube machine that assembles multiple bare or insulated wires into a concentric stranded<\/p>","protected":false},"author":1,"featured_media":31169,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[565],"tags":[],"class_list":["post-31162","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized-en"],"_links":{"self":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/comments?post=31162"}],"version-history":[{"count":1,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31162\/revisions"}],"predecessor-version":[{"id":31170,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/posts\/31162\/revisions\/31170"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media\/31169"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media?parent=31162"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/categories?post=31162"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/tags?post=31162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}