{"id":28636,"date":"2026-04-26T07:22:38","date_gmt":"2026-04-26T07:22:38","guid":{"rendered":"https:\/\/doingcable.com\/?post_type=product&#038;p=28636"},"modified":"2026-07-31T13:20:50","modified_gmt":"2026-07-31T13:20:50","slug":"adss-all-dielectric-self-supporting-aerial-cable","status":"publish","type":"product","link":"https:\/\/doingcable.com\/ar\/product\/adss-all-dielectric-self-supporting-aerial-cable\/","title":{"rendered":"\u0643\u0627\u0628\u0644 \u0647\u0648\u0627\u0626\u064a \u0630\u0627\u062a\u064a \u0627\u0644\u062f\u0639\u0645 \u0645\u0635\u0646\u0648\u0639 \u0628\u0627\u0644\u0643\u0627\u0645\u0644 \u0645\u0646 \u0645\u0648\u0627\u062f \u0639\u0627\u0632\u0644\u0629 (ADSS)"},"content":{"rendered":"<p dir=\"auto\"><strong>\u0643\u0627\u0628\u0644 \u0647\u0648\u0627\u0626\u064a \u0630\u0627\u062a\u064a \u0627\u0644\u062f\u0639\u0645 \u0645\u0635\u0646\u0648\u0639 \u0628\u0627\u0644\u0643\u0627\u0645\u0644 \u0645\u0646 \u0645\u0648\u0627\u062f \u0639\u0627\u0632\u0644\u0629 (ADSS)<\/strong> is a fully non-metallic optical fiber cable engineered for self-supporting aerial installation on utility poles and high-voltage transmission towers. Unlike traditional cables that require a separate messenger wire, ADSS integrates high-strength aramid yarn as the primary tensile member, enabling direct stringing between structures while remaining completely immune to electromagnetic interference and lightning-induced currents.<\/p>\n<p dir=\"auto\">The cable is designed for live-line installation on energized power lines without service interruption \u2014 a decisive advantage for utility communication upgrades, smart-grid projects, and rural broadband expansion. With a typical design life of 30 years and compliance with IEEE 1222 and IEC 60794 series standards, ADSS delivers reliable long-term performance under wind, ice, UV, and temperature extremes from \u201340 \u00b0C to +70 \u00b0C.<\/p>\n<p dir=\"auto\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-28653\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-400x229.png\" alt=\"All Dielectric Self-supporting Aerial Cable (ADSS)\" width=\"421\" height=\"241\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-400x229.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-430x247.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-250x143.png 250w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-700x402.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6-768x441.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/20a9996c014e69d55d7b0bde42d50a6.png 950w\" sizes=\"(max-width: 421px) 100vw, 421px\" \/><\/p>\n<p dir=\"auto\">Because ADSS contains <strong>no metallic components<\/strong>, it requires no grounding and can be installed directly in the supply space of live lines without electrical hazard \u2014 making it the preferred choice for utilities seeking rapid deployment and long-term reliability.<\/p>\n<p dir=\"auto\"><img decoding=\"async\" class=\"alignnone size-full wp-image-30252\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable.webp\" alt=\"ADSS Optical Fiber Cable\" width=\"680\" height=\"499\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable.webp 680w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable-400x294.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable-16x12.webp 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable-430x316.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Optical-Fiber-Cable-250x183.webp 250w\" sizes=\"(max-width: 680px) 100vw, 680px\" \/><\/p>\n<p dir=\"auto\"><strong>Typical ADSS cross-section<\/strong> showing loose tubes, aramid yarn strength members, and all-dielectric construction.<\/p>\n<h2 dir=\"auto\">What Is ADSS Cable and Why Is It Chosen for Power Line Corridors?<\/h2>\n<p dir=\"auto\">ADSS cable contains no metallic components. Optical fibers sit in gel-filled or dry loose tubes around a central FRP strength member. Layers of water-blocked aramid (Kevlar-type) yarns provide the tensile load path. An outer PE or AT polyethylene jacket protects against UV, moisture and electrical tracking. Typical fiber counts range from 12 to 288 (up to 864 in specialized designs). Operating temperature is \u201340 \u00b0C to +70 \u00b0C. Attenuation for G.652.D single-mode fiber remains \u22640.35 dB\/km at 1310 nm and \u22640.22 dB\/km at 1550 nm under full mechanical load.<\/p>\n<p dir=\"auto\">Because the cable is entirely dielectric, it can be installed while the power line remains energized. This eliminates the outage cost and scheduling constraints associated with OPGW replacement of the existing ground wire. Typical installed cost is 60\u201380 % of an OPGW retrofit on the same route. Design life is 25\u201330 years when span, sag, ice\/wind loading and electric-field exposure are correctly engineered.<\/p>\n<h3 dir=\"auto\">Cable Construction<\/h3>\n<ul dir=\"auto\">\n<li>Optical fibers (G.652D \/ G.657A single-mode or multimode) housed in gel-filled or dry-blocked PBT loose tubes<\/li>\n<li>Non-metallic FRP (Fiber Reinforced Plastic) central strength member<\/li>\n<li>SZ-stranded cable core with water-blocking yarns or tapes<\/li>\n<li>Optional thin PE inner sheath<\/li>\n<li>High-modulus aramid yarn strength layer (quantity and pitch engineered per span and load)<\/li>\n<li>Outer sheath: standard PE for lines \u2264 110 kV or anti-tracking (AT) compound for lines \u2265 110 kV (up to 220 kV and beyond with field analysis)<\/li>\n<\/ul>\n<p dir=\"auto\">This all-dielectric structure eliminates the need for grounding or bonding and significantly reduces tower loading compared with metallic alternatives such as OPGW.<\/p>\n<h2 dir=\"auto\">Primary Applications of ADSS Fiber Optic Cable<\/h2>\n<p dir=\"auto\">ADSS excels across a wide range of high-voltage environments:<\/p>\n<ul dir=\"auto\">\n<li>Long-span aerial deployments on transmission and distribution lines (typical spans 50\u20131000 m, up to 1500 m in specialized designs)<\/li>\n<li>Smart-grid communications, SCADA systems, and utility private networks<\/li>\n<li>Fiber-to-the-home (FTTH) and middle-mile backbone extensions along power corridors<\/li>\n<li>Renewable energy projects, rural electrification, and grid modernization initiatives<\/li>\n<li>Environments requiring complete immunity to electromagnetic interference (EMI)<\/li>\n<\/ul>\n<p dir=\"auto\">Its lightweight profile and non-conductive nature make it ideal for retrofitting existing lines where adding metallic cables would increase loading or require extensive grounding work.<\/p>\n<h3 dir=\"auto\">Comparison of aerial optical cable types<\/h3>\n<table style=\"height: 319px;\" width=\"1178\">\n<thead>\n<tr>\n<th data-col-size=\"lg\">\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th data-col-size=\"md\">ADSS<\/th>\n<th data-col-size=\"md\">OPGW<\/th>\n<th data-col-size=\"md\">Figure-8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"lg\">Metallic content<\/td>\n<td data-col-size=\"md\">None<\/td>\n<td data-col-size=\"md\">Aluminum-clad steel \/ alloy<\/td>\n<td data-col-size=\"md\">Steel messenger<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Primary function<\/td>\n<td data-col-size=\"md\">Communication only<\/td>\n<td data-col-size=\"md\">Shield + communication<\/td>\n<td data-col-size=\"md\">Communication only<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Installation outage<\/td>\n<td data-col-size=\"md\">Not required<\/td>\n<td data-col-size=\"md\">Required<\/td>\n<td data-col-size=\"md\">Not required<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Typical weight<\/td>\n<td data-col-size=\"md\">80\u2013250 kg\/km<\/td>\n<td data-col-size=\"md\">400\u2013700 kg\/km<\/td>\n<td data-col-size=\"md\">150\u2013350 kg\/km<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Max practical span<\/td>\n<td data-col-size=\"md\">100\u20131 500 m (custom to 2 600 m)<\/td>\n<td data-col-size=\"md\">1 000\u20133 000 m<\/td>\n<td data-col-size=\"md\">50\u2013200 m<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Voltage environment<\/td>\n<td data-col-size=\"md\">\u2264500 kV (AT jacket)<\/td>\n<td data-col-size=\"md\">Unlimited (metallic)<\/td>\n<td data-col-size=\"md\">Distribution only<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Lightning \/ fault current<\/td>\n<td data-col-size=\"md\">None<\/td>\n<td data-col-size=\"md\">Carries full current<\/td>\n<td data-col-size=\"md\">None<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Dry-band arcing risk<\/td>\n<td data-col-size=\"md\">Present above ~12 kV space potential<\/td>\n<td data-col-size=\"md\">None<\/td>\n<td data-col-size=\"md\">\u0645\u0646\u062e\u0641\u0636<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Relative installed cost (retrofit)<\/td>\n<td data-col-size=\"md\">Lowest<\/td>\n<td data-col-size=\"md\">Highest<\/td>\n<td data-col-size=\"md\">\u0645\u062a\u0648\u0633\u0637<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"auto\">Data compiled from IEC 60794-4-20, IEEE 1222-2019\/2025 corrigendum, and manufacturer datasheets (Corning, Prysmian, Hengtong, Sterlite, AFL).<\/p>\n<h3 dir=\"auto\">Key Advantages of ADSS Aerial Cable<\/h3>\n<ul dir=\"auto\">\n<li><strong>Self-Supporting &amp; Easy Installation<\/strong> \u2014 No messenger wire or extra hardware needed; utilizes existing poles and towers, significantly reducing installation time, labor, and overall project cost.<\/li>\n<li><strong>Fully Dielectric &amp; EMI Immune<\/strong> \u2014 Zero metallic components eliminate grounding requirements and provide complete immunity to electromagnetic interference, ensuring stable optical performance near high-voltage conductors.<\/li>\n<li><strong>Live-Line Installation Capability<\/strong> \u2014 Can be installed safely on energized lines, minimizing service interruptions during deployment.<\/li>\n<li><strong>High Mechanical Strength &amp; Durability<\/strong> \u2014 Reinforced with high-modulus aramid yarn for excellent tensile performance, bullet resistance, and outstanding resistance to wind, ice, UV radiation, and extreme temperatures.<\/li>\n<li><strong>Lightweight &amp; Low Tower Loading<\/strong> \u2014 Small diameter and low weight reduce mechanical stress on support structures compared with traditional metallic or lashed cables.<\/li>\n<li><strong>Long-Span Performance<\/strong> \u2014 Engineered for spans from 50 m to over 1000 m depending on fiber count and environmental conditions.<\/li>\n<li><strong>Excellent Optical Performance<\/strong> \u2014 Optimized for single-mode transmission at 1310 nm and 1550 nm with low attenuation and high bandwidth.<\/li>\n<\/ul>\n<p dir=\"auto\"><img decoding=\"async\" class=\"alignnone size-full wp-image-30253\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable.jpg\" alt=\"ADSS Cable\" width=\"870\" height=\"490\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable.jpg 870w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-400x225.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-768x433.jpg 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-18x10.jpg 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-430x242.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-700x394.jpg 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/ADSS-Cable-250x141.jpg 250w\" sizes=\"(max-width: 870px) 100vw, 870px\" \/><\/p>\n<p dir=\"auto\"><strong>ADSS cable construction<\/strong> \u2014 aramid yarn strength members, loose tubes, and UV-resistant outer jacket designed for long-term aerial exposure.<\/p>\n<h3 dir=\"auto\">Construction and Design Features<\/h3>\n<p dir=\"auto\">ADSS cables typically feature a loose-tube design with:<\/p>\n<ul dir=\"auto\">\n<li>Multiple colored loose tubes containing optical fibers (commonly 2\u2013144 fibers)<\/li>\n<li>Water-blocking gel or dry water-blocking materials<\/li>\n<li>Central strength member (FRP) and peripheral high-strength aramid yarn<\/li>\n<li>UV-stabilized polyethylene (PE) outer jacket; AT (anti-tracking) jacket available for high electric field environments<\/li>\n<\/ul>\n<p dir=\"auto\">The all-dielectric structure ensures the cable remains lightweight while delivering the mechanical robustness required for long-term aerial service in harsh climates.<\/p>\n<h3 dir=\"auto\">Typical Technical Parameters<\/h3>\n<table style=\"height: 269px;\" width=\"539\">\n<thead>\n<tr>\n<th data-col-size=\"lg\">\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th data-col-size=\"md\">Typical Range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"lg\">Fiber Count<\/td>\n<td data-col-size=\"md\">2 \u2013 288 cores<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u0627\u0644\u0642\u0637\u0631 \u0627\u0644\u062e\u0627\u0631\u062c\u064a<\/td>\n<td data-col-size=\"md\">10 \u2013 18 mm (depends on design)<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Cable Weight<\/td>\n<td data-col-size=\"md\">90 \u2013 280 kg\/km<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Max Working Tension (MAT)<\/td>\n<td data-col-size=\"md\">1.5 \u2013 20+ kN<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Break Strength (UTS)<\/td>\n<td data-col-size=\"md\">10 \u2013 120 kN<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Suitable Span (NESC)<\/td>\n<td data-col-size=\"md\">50 \u2013 1000 m+<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td data-col-size=\"md\">\u201340 \u00b0C to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/td>\n<td data-col-size=\"md\">IEEE 1222, IEC 60794-1 \/ 60794-4-20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"auto\">Exact values are engineered per project (span, wind\/ice loading, voltage class, fiber type). Custom designs available upon request.<\/p>\n<h3 dir=\"auto\">Technical Performance Highlights<\/h3>\n<ul dir=\"auto\">\n<li><strong>Fiber Compatibility<\/strong>: Standard single-mode (G.652D, G.655) and bend-insensitive fibers (G.657)<\/li>\n<li><strong>Attenuation<\/strong>: Typically \u2264 0.35 dB\/km @ 1310 nm and \u2264 0.21 dB\/km @ 1550 nm<\/li>\n<li><strong>Temperature Range<\/strong>: -40\u00b0C to +70\u00b0C (operational)<\/li>\n<li><strong>Span Capability<\/strong>: 100\u20131500 m (design-dependent)<\/li>\n<li><strong>Crush &amp; Tensile Resistance<\/strong>: High crush resistance and tensile strength tailored to span and environmental loading<\/li>\n<\/ul>\n<h3 dir=\"auto\">\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0648\u0636\u0645\u0627\u0646 \u0627\u0644\u062c\u0648\u062f\u0629<\/h3>\n<p dir=\"auto\">RLB ADSS cables are designed and tested in full compliance with <strong>IEEE 1222<\/strong> and relevant IEC 60794 series standards. This ensures verified mechanical, electrical (tracking resistance), and optical performance, with a typical service life of 30+ years under demanding aerial conditions.<\/p>\n<p dir=\"auto\">Cables are supplied on heavy-duty wooden or steel-wooden drums for safe handling and deployment.<\/p>\n<h3 dir=\"auto\">ADSS vs OPGW: Choosing the Right Aerial Fiber Solution<\/h3>\n<p dir=\"auto\">While both ADSS and OPGW are used on power lines, they serve different primary functions:<\/p>\n<ul dir=\"auto\">\n<li><strong>ADSS<\/strong> \u2014 Dedicated communication cable; all-dielectric, lightweight, lower cost, ideal for retrofitting existing lines and live-line installation.<\/li>\n<li><strong>OPGW<\/strong> \u2014 Dual-function (ground wire + communication); contains metallic elements for lightning protection and fault current carrying; typically used on new transmission line construction.<\/li>\n<\/ul>\n<p dir=\"auto\">Many utilities deploy both: OPGW on transmission lines and ADSS on distribution or for additional capacity on existing corridors.<\/p>\n<h3 dir=\"auto\">Quality &amp; Customization Commitment<\/h3>\n<p dir=\"auto\">As a technology-driven manufacturer focused on long-term cooperation, we engineer every ADSS cable to the specific mechanical, electrical and environmental conditions of your route. Fiber type, core count, span rating, sheath type (PE\/AT), and packaging are fully customizable. All cables undergo 100 % OTDR testing and mechanical verification to ensure consistent optical and tensile performance over the full 30-year design life.<\/p>\n<p dir=\"auto\"><strong>\u0627\u0633\u062a\u0641\u0633\u0631 \u0627\u0644\u0622\u0646<\/strong> to discuss ADSS configurations, span calculations, technical specifications, or complete aerial fiber solutions tailored to your transmission or distribution project. Our team delivers professional consultation, customized designs, and reliable long-term partnership.<\/p>","protected":false},"excerpt":{"rendered":"<p dir=\"auto\">\u0643\u0627\u0628\u0644 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0636\u0648\u0626\u064a\u0629 \u0627\u0644\u062d\u0627\u0645\u0644 \u0628\u0646\u0641\u0633\u0647 \u0628\u0627\u0644\u0643\u0627\u0645\u0644 \u0627\u0644\u0639\u0627\u0632\u0644 (\u0643\u0627\u0628\u0644 ADSS) \u060c \u0648\u0627\u0644\u0645\u0639\u0631\u0648\u0641 \u0623\u064a\u0636\u064b\u0627 \u0628\u0627\u0633\u0645 \u0643\u0627\u0628\u0644 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0636\u0648\u0626\u064a\u0629 ADSS \u060c \u0647\u0648 \u0643\u0627\u0628\u0644 \u0623\u0644\u064a\u0627\u0641 \u0636\u0648\u0626\u064a\u0629 \u0647\u0648\u0627\u0626\u064a \u063a\u064a\u0631 \u0645\u0639\u062f\u0646\u064a \u0628\u0627\u0644\u0643\u0627\u0645\u0644 \u0648\u0645\u0633\u062a\u0642\u0644 \u0628\u0630\u0627\u062a\u0647 \u0645\u0635\u0645\u0645 \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u0644\u062a\u062b\u0628\u064a\u062a \u0639\u0644\u0649 \u062e\u0637\u0648\u0637 \u0646\u0642\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a. \u0628\u0641\u0636\u0644 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0645\u0643\u0648\u0646\u0627\u062a \u0645\u0648\u0635\u0644\u0629 \u060c \u064a\u0644\u063a\u064a \u0643\u0627\u0628\u0644 ADSS \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0623\u0648 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0631\u0633\u0648\u0644 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629 \u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0627\u0644\u062e\u064a\u0627\u0631 \u0627\u0644\u0645\u0641\u0636\u0644 \u0644\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u062a\u064a \u062a\u0633\u0639\u0649 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0628\u0646\u064a\u0629 \u062a\u062d\u062a\u064a\u0629 \u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0622\u0645\u0646\u0629 \u0648\u0641\u0639\u0627\u0644\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0648\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u062f\u0627\u0621 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u0643\u0647\u0631\u0628\u0629.<\/p>","protected":false},"featured_media":29405,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_brand":[],"product_cat":[21,91,96],"product_tag":[115,1107,1109,1108,1106,1110,1111],"class_list":{"0":"post-28636","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-product","7":"product_cat-cable-material","8":"product_cat-optical-cable","9":"product_tag-adss-cable","10":"product_tag-adss-fiber-optic","11":"product_tag-adss-vs-opgw","12":"product_tag-aerial-fiber-on-power-lines","13":"product_tag-all-dielectric-self-supporting-aerial-cable","14":"product_tag-smart-grid-communication","15":"product_tag-utility-fiber-deployment","17":"first","18":"instock","19":"shipping-taxable","20":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product\/28636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/comments?post=28636"}],"version-history":[{"count":7,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product\/28636\/revisions"}],"predecessor-version":[{"id":30929,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product\/28636\/revisions\/30929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media\/29405"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/media?parent=28636"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product_brand?post=28636"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product_cat?post=28636"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/doingcable.com\/ar\/wp-json\/wp\/v2\/product_tag?post=28636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}