{"id":31067,"date":"2026-08-23T08:42:09","date_gmt":"2026-08-23T08:42:09","guid":{"rendered":"https:\/\/doingcable.com\/?p=31067"},"modified":"2026-08-23T08:42:11","modified_gmt":"2026-08-23T08:42:11","slug":"what-is-continuous-interlock-armouring-machine","status":"publish","type":"post","link":"https:\/\/doingcable.com\/fr\/what-is-continuous-interlock-armouring-machine\/","title":{"rendered":"Qu'est-ce qu'une machine de blindage \u00e0 feuillard embo\u00eet\u00e9 en continu ?"},"content":{"rendered":"<p><strong>Machine de blindage \u00e0 verrouillage continu<\/strong> is a specialized high-speed production line used in cable manufacturing to apply a continuous, interlocked metal strip armour around round or flat cable cores. It forms a flexible, self-locking helical metal sheath (typically aluminum alloy, galvanized steel, stainless steel or copper strip) that provides superior mechanical protection, crush resistance, tensile strength and flexibility without requiring rigid conduit.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/doingcable.com\/fr\/produit\/machine-de-blindage-a-verrouillage-continu\/\">inquiry now<\/a><\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"600\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable.jpg\" alt=\"\" class=\"wp-image-31068\" style=\"width:575px;height:auto\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable.jpg 900w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-400x267.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-768x512.jpg 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-18x12.jpg 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-430x287.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-700x467.jpg 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Continuous-Interlocking-Armoring-Machine-doingcable-250x167.jpg 250w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p>This machine is the core equipment for producing Type MC (Metal-Clad), AC, BX, aluminum-alloy interlocked armour cables, submersible oil-pump (ESP) cables, fire-resistant cables and flexible metallic conduits. Unlike traditional tape-wrapping or wire-armouring methods, the continuous interlock process creates an S-shaped or corrugated interlocked profile in one continuous pass, enabling high line speeds and consistent armour integrity.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Working Principle of Continuous Interlock Armouring<\/h3>\n\n\n\n<p>A continuous interlock armouring machine feeds a flat metal strip (width 9.5\u201325.4 mm, thickness 0.5\u20130.8 mm) from a pay-off or accumulator. The strip passes through forming rollers that shape it into an S-profile or interlocked corrugation. The rotating head (or forming die system) spirally wraps the pre-formed strip around the advancing cable core so that each successive turn interlocks with the previous one, creating a continuous flexible metal tube.<\/p>\n\n\n\n<p>Key process elements include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Precise strip tension control (servo or pneumatic)<\/li>\n\n\n\n<li>Synchronized rotation of the armouring head (up to 1200 rpm on smaller models)<\/li>\n\n\n\n<li>Capstan or caterpillar haul-off that matches linear speed to pitch<\/li>\n\n\n\n<li>Automatic pitch and diameter adjustment via PLC<\/li>\n<\/ul>\n\n\n\n<p>The result is a tightly interlocked armour with typical pitch of 6.0\u201312.7 mm that remains flexible yet highly resistant to crush and impact.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Technical Parameters and Model Comparison<\/h3>\n\n\n\n<p>Typical production range for modern continuous interlock lines:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Mod\u00e8le<\/th><th>Max Cable OD (mm)<\/th><th>Max Rotation Speed (rpm)<\/th><th>Strip Width \u00d7 Thickness (mm)<\/th><th>Main Motor (kW)<\/th><th>Typical Line Speed (m\/min)<\/th><th>Primary Application<\/th><\/tr><\/thead><tbody><tr><td>50 \/ RLH-50<\/td><td>6\u201345 \/ \u03a650<\/td><td>1000\u20131200<\/td><td>9.5\u201312.7 \u00d7 0.5\u20130.65<\/td><td>18.5\u201322<\/td><td>up to 10\u201312<\/td><td>Round &amp; flat ESP \/ Al-alloy cable<\/td><\/tr><tr><td>100 \/ LSKZ-100<\/td><td>10\u201395<\/td><td>800<\/td><td>9.5\u201319 \/ 25.4 \u00d7 0.5\u20130.65<\/td><td>22<\/td><td>8\u201313.6<\/td><td>MC \/ AC \/ fire-proof cables<\/td><\/tr><tr><td>130<\/td><td>10\u2013125 \/ \u03a6130<\/td><td>700\u2013800<\/td><td>9.5\u201325.4 \u00d7 0.5\u20130.8<\/td><td>22<\/td><td>6\u201311<\/td><td>Large power &amp; instrument cables<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Data compiled from leading manufacturers (RLB, Handing, Herrman, Bartell-type lines). Center height is commonly 1000 mm. Control systems follow IEC standards with Siemens or equivalent PLC + HMI for pitch, tension and diameter closed-loop control.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comparison: Continuous Interlock vs Other Armouring Methods<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Fonctionnalit\u00e9<\/th><th>Continuous Interlock Armour<\/th><th>Steel-Wire Armour (SWA)<\/th><th>Corrugated Welded Armour (CCW)<\/th><th>Traditional Tape Wrap<\/th><\/tr><\/thead><tbody><tr><td>Flexibility<\/td><td>Excellent<\/td><td>Limit\u00e9<\/td><td>Mod\u00e9r\u00e9<\/td><td>Poor<\/td><\/tr><tr><td>Crush \/ Impact Resistance<\/td><td>Haut<\/td><td>Very High<\/td><td>Haut<\/td><td>Mod\u00e9r\u00e9<\/td><\/tr><tr><td>Installation Speed<\/td><td>Fast (no conduit needed)<\/td><td>Slow<\/td><td>Mod\u00e9r\u00e9<\/td><td>Slow<\/td><\/tr><tr><td>Poids<\/td><td>Light (Al option)<\/td><td>Heavy<\/td><td>Medium<\/td><td>Medium<\/td><\/tr><tr><td>Production Speed<\/td><td>High continuous<\/td><td>Medium<\/td><td>Medium<\/td><td>Faible<\/td><\/tr><tr><td>Typical Standards<\/td><td>UL 1569 \/ NEC Type MC, CSA<\/td><td>IEC 60502, GB<\/td><td>IEC \/ API<\/td><td>Various<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Interlocked armour is preferred for North American MC\/AC cables, oil &amp; gas ESP cables, data\/fiber protection and commercial building wiring where bend radius and ease of installation are critical.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Applications and Selection Logic<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Aluminum-alloy interlocked armour cables<\/strong> (AC90, ACWU90, MC) \u2013 building and industrial power distribution.<\/li>\n\n\n\n<li><strong>Submersible oil-pump (ESP) cables<\/strong> \u2013 continuous flexible protection in harsh downhole environments.<\/li>\n\n\n\n<li><strong>Fire-resistant and instrument cables<\/strong> \u2013 mechanical integrity under fire and vibration.<\/li>\n\n\n\n<li><strong>Flexible metallic conduit (FMC \/ BX)<\/strong> \u2013 commercial and residential wiring.<\/li>\n\n\n\n<li><strong>Data, coaxial and fiber-optic protection<\/strong> \u2013 where crush resistance and flexibility are both required.<\/li>\n<\/ul>\n\n\n\n<p>Selection criteria for engineers and procurement:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Maximum finished cable diameter and core type (round vs flat).<\/li>\n\n\n\n<li>Required strip material (aluminum alloy for weight reduction, galvanized steel for higher strength, stainless for corrosion).<\/li>\n\n\n\n<li>Target pitch and armour coverage percentage.<\/li>\n\n\n\n<li>Production volume \u2192 choose high-rpm models (50-series) for smaller diameters or 100\/130-series for larger cables.<\/li>\n\n\n\n<li>Integration needs: pay-off size (PN800\u2013PN1250), caterpillar haul-off, take-up with traverse, and accumulator for continuous strip feed.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" width=\"1067\" height=\"800\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-1067x800.webp\" alt=\"\" class=\"wp-image-31070\" style=\"width:751px;height:auto\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-1067x800.webp 1067w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-400x300.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-768x576.webp 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-16x12.webp 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-430x323.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-700x525.webp 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable-250x188.webp 250w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Strip-Armouring-Equipment-doingcable.webp 1200w\" sizes=\"(max-width: 1067px) 100vw, 1067px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Standards, Performance Data and Reliability Considerations<\/h3>\n\n\n\n<p>Modern machines are designed to produce armour complying with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>UL 1569 \/ NEC Type MC<\/li>\n\n\n\n<li>CSA standards for AC\/MC cables<\/li>\n\n\n\n<li>ICEA recommended interlocked armour thicknesses<\/li>\n\n\n\n<li>IEC electrical equipment safety requirements for the machine itself<\/li>\n<\/ul>\n\n\n\n<p>Typical performance metrics observed in 2024\u20132026 production lines:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Armour tensile and crush resistance significantly higher than non-interlocked constructions.<\/li>\n\n\n\n<li>Bend radius performance superior to wire armour, enabling tighter installation routes.<\/li>\n\n\n\n<li>Continuous operation capability with automatic strip changeover systems that minimize downtime.<\/li>\n<\/ul>\n\n\n\n<p>Modes de d\u00e9faillance courants et pr\u00e9vention :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Uneven interlocking or gaps \u2192 maintain precise strip tension and forming-roll alignment.<\/li>\n\n\n\n<li>Strip breakage \u2192 use quality strip material and proper accumulator control.<\/li>\n\n\n\n<li>Diameter variation \u2192 closed-loop diameter measurement and real-time pitch adjustment.<\/li>\n\n\n\n<li>Excessive vibration at high rpm \u2192 dynamic balancing of the rotating head and proper foundation.<\/li>\n<\/ul>\n\n\n\n<p>Regular maintenance focuses on forming dies, guide rollers, bearings of the rotating system, and servo tension units. Proper lubrication and periodic calibration of pitch and tension sensors are essential for long-term dimensional stability.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"749\" height=\"552\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable.avif\" alt=\"\" class=\"wp-image-31071\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable.avif 749w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable-400x295.avif 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable-16x12.avif 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable-430x317.avif 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable-700x516.avif 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/08\/Aluminium-Interlock-Strip-Armoring-Machine-doingcable-250x184.avif 250w\" sizes=\"(max-width: 749px) 100vw, 749px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Summary of Technical Advantages<\/h3>\n\n\n\n<p>Continuous Interlock Armouring Machines deliver:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High productivity through continuous high-speed operation (up to 1200 rpm on smaller models).<\/li>\n\n\n\n<li>Consistent interlocking geometry that provides both flexibility and mechanical strength.<\/li>\n\n\n\n<li>Compatibility with aluminum, steel, stainless and copper strips for optimized cost\/weight\/performance.<\/li>\n\n\n\n<li>Full line integration capability for modern cable factories producing MC, ESP, fire-resistant and specialty cables.<\/li>\n<\/ul>\n\n\n\n<p>For cable manufacturers seeking reliable quality, customized engineering solutions and long-term production partnership, precise machine selection based on diameter range, material and target standards is critical.<\/p>\n\n\n\n<p><strong>Demande d&#039;informations<\/strong> for detailed technical proposals, layout drawings, capacity calculations or customized continuous interlock armouring lines tailored to your cable product range.<\/p>","protected":false},"excerpt":{"rendered":"<p>Continuous Interlock Armouring Machine is a specialized high-speed production line used in cable manufacturing to apply a continuous, interlocked metal<\/p>","protected":false},"author":1,"featured_media":31072,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[565],"tags":[],"class_list":["post-31067","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized-en"],"_links":{"self":[{"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/posts\/31067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/comments?post=31067"}],"version-history":[{"count":1,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/posts\/31067\/revisions"}],"predecessor-version":[{"id":31073,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/posts\/31067\/revisions\/31073"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/media\/31072"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/media?parent=31067"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/categories?post=31067"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/doingcable.com\/fr\/wp-json\/wp\/v2\/tags?post=31067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}