{"id":28479,"date":"2026-04-26T06:57:27","date_gmt":"2026-04-26T06:57:27","guid":{"rendered":"https:\/\/doingcable.com\/?post_type=product&#038;p=28479"},"modified":"2026-05-21T19:48:29","modified_gmt":"2026-05-21T19:48:29","slug":"yardimci-ekipman-kapali-sogutma-kulesi","status":"publish","type":"product","link":"https:\/\/doingcable.com\/tr\/product\/yardimci-ekipman-kapali-sogutma-kulesi\/","title":{"rendered":"Yard\u0131mc\u0131 Ekipman Kapal\u0131 So\u011futma Kulesi"},"content":{"rendered":"<p dir=\"auto\">In high-volume wire and cable manufacturing, maintaining precise temperature control for critical production equipment is non-negotiable. The <strong>closed cooling tower<\/strong> (also known as a closed circuit cooling tower or water cooling tower for cooling industrial equipments) delivers reliable, contamination-free heat rejection that directly supports the continuous operation of <strong>tel b\u00fckme makinesi<\/strong>, <strong>demetleme makinesi<\/strong>, <strong>tel \u00e7ekme makinesi<\/strong>, and related auxiliary systems.<\/p>\n<p dir=\"auto\">Unlike traditional open-circuit towers, this fully enclosed solution circulates process fluids through sealed heat exchanger coils, eliminating direct contact with ambient air or spray water. The result: zero risk of scaling, corrosion, or biological contamination\u2014critical for maintaining the consistent performance and extended service life of high-speed cable production lines.<\/p>\n<p dir=\"auto\">Engineered for demanding industrial environments, our closed cooling towers ensure stable cooling of water, brine, quenching oils, annealing fluids, and specialized media used in wire drawing, stranding, and bunching processes. They combine evaporative and air-cooling mechanisms in a compact footprint, delivering superior energy efficiency, minimal water loss, and full compliance with stringent environmental and safety standards.<\/p>\n<p dir=\"auto\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-28916\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15.png\" alt=\"A\u00e7\u0131k ve Kapal\u0131 Devre So\u011futma Kulelerinin T\u00fcrleri ve Fonksiyonlar\u0131\" width=\"777\" height=\"414\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15.png 937w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15-400x213.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15-768x409.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15-430x229.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15-700x373.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/c9dc42d73d7e128d9c4f32849a0fd15-150x80.png 150w\" sizes=\"(max-width: 777px) 100vw, 777px\" \/><\/p>\n<h3 dir=\"auto\">Working Principle of Closed Cooling Towers<\/h3>\n<p dir=\"auto\">Closed circuit cooling towers operate on a proven dual-circuit design that guarantees complete hydraulic separation between the process fluid and the external cooling medium:<\/p>\n<ul dir=\"auto\">\n<li><strong>Internal closed loop<\/strong>: The hot process fluid (from wire drawing machine capstans, stranding machine bearings, bunching machine drives, or annealing lines) flows inside finned coils.<\/li>\n<li><strong>External evaporative loop<\/strong>: Recirculating spray water is distributed over the coil surface while axial fans draw ambient air through the tower, accelerating evaporation and heat transfer.<\/li>\n<\/ul>\n<p dir=\"auto\">Heat moves from the process fluid through the coil walls to the spray water, then dissipates to the atmosphere via latent heat of evaporation. The cooled fluid returns to the production equipment without ever mixing with spray water or outside air. This double-cooling effect (sensible + latent heat transfer) achieves higher overall efficiency than dry coolers while maintaining a fully closed, contaminant-free system.<\/p>\n<p dir=\"auto\">The vertical or modular prying-type design further optimizes airflow and heat exchange, making the unit ideal for integration with high-speed <strong>tel b\u00fckme makinesi<\/strong>, <strong>demetleme makinesi<\/strong>, Ve <strong>tel \u00e7ekme makinesi<\/strong> lines where space and uptime are paramount.<\/p>\n<div aria-label=\"A\u00e7\u0131k ve Kapal\u0131 Devre So\u011futma Kulelerinin T\u00fcrleri ve Fonksiyonlar\u0131\" data-testid=\"image-viewer\">\n<div><img decoding=\"async\" class=\"alignnone wp-image-28917\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850.png\" alt=\"A\u00e7\u0131k ve Kapal\u0131 Devre So\u011futma Kulelerinin T\u00fcrleri ve Fonksiyonlar\u0131\" width=\"793\" height=\"500\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850.png 905w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850-400x252.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850-768x485.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850-430x271.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850-700x442.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/f2b85774e9d33c48238439871caf850-150x95.png 150w\" sizes=\"(max-width: 793px) 100vw, 793px\" \/><\/div>\n<div>\n<h3 dir=\"auto\">Geleneksel A\u00e7\u0131k So\u011futma Kulelerine G\u00f6re Ba\u015fl\u0131ca Avantajlar\u0131<\/h3>\n<p dir=\"auto\">Our closed cooling towers are purpose-built to solve the real-world pain points of cable manufacturers:<\/p>\n<ul dir=\"auto\">\n<li><strong>Zero Contamination &amp; Extended Equipment Life<\/strong> \u2014 Complete isolation prevents dust, debris, and airborne particles from entering the process loop, eliminating pipeline blockages and protecting precision components in wire drawing dies, stranding heads, and bunching flyers.<\/li>\n<li><strong>Soft Water Circulation with No Scaling<\/strong> \u2014 Uses treated soft water in the closed loop, dramatically reducing scaling on heat-exchange surfaces and preventing overheating\u2014directly translating to fewer production stops on <strong>tel \u00e7ekme makinesi<\/strong> and annealing equipment.<\/li>\n<li><strong>Superior Energy Efficiency &amp; Lower Operating Costs<\/strong> \u2014 Combines evaporative cooling with intelligent fan\/pump control, achieving up to 30-40% lower power consumption compared to open towers + plate heat exchanger combinations. Real-world data from global cable plants show significant savings in electricity and water treatment chemicals.<\/li>\n<li><strong>Automatic Digital PLC Control<\/strong> \u2014 Precise temperature regulation (\u00b11\u00b0C), remote monitoring, automatic mode switching (wet\/dry), and fault diagnostics minimize operator intervention and ensure 24\/7 reliability.<\/li>\n<li><strong>Environmental Protection &amp; Water Savings<\/strong> \u2014 Near-zero process fluid loss, no chemical dosing in the closed loop, and compliance with strict discharge regulations\u2014ideal for facilities targeting ESG goals.<\/li>\n<li><strong>Modular Prying-Type Design<\/strong> \u2014 Plug-and-play installation with simple piping; no need for large reservoirs or extensive civil works. Reduced footprint improves factory layout efficiency when pairing with multiple <strong>tel b\u00fckme makinesi<\/strong> veya <strong>demetleme makinesi<\/strong> units.<\/li>\n<li><strong>\u00c7ok Y\u00f6nl\u00fc Medya Uyumlulu\u011fu<\/strong> \u2014 Handles water, oil, glycol mixtures, quenching liquids, and chemical solutions without altering fluid composition\u2014perfect for specialty cable production.<\/li>\n<\/ul>\n<p dir=\"auto\">These advantages deliver measurable ROI: longer equipment uptime, lower maintenance, reduced labor, and consistent product quality in fire-resistant, control, and communication cable lines.<\/p>\n<p dir=\"auto\"><img decoding=\"async\" class=\"alignnone wp-image-28918\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4.png\" alt=\"Kapal\u0131 Devre ve A\u00e7\u0131k Devre So\u011futma Kuleleri\" width=\"874\" height=\"452\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4.png 1191w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4-400x207.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4-768x397.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4-430x222.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4-700x362.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/d673861cda6b632c3c63b0da9996cf4-150x78.png 150w\" sizes=\"(max-width: 874px) 100vw, 874px\" \/><\/p>\n<h3 dir=\"auto\">Teknik \u00d6zellikler (Standart Modeller)<\/h3>\n<table style=\"height: 433px;\" width=\"937\">\n<thead>\n<tr>\n<th data-col-size=\"md\">Model<\/th>\n<th data-col-size=\"sm\">So\u011futma Kapasitesi (kW)<\/th>\n<th data-col-size=\"lg\">Motor G\u00fcc\u00fc (kW)<\/th>\n<th data-col-size=\"xl\">Fan Debisi (m\u00b3\/h)<\/th>\n<th data-col-size=\"sm\">P\u00fcsk\u00fcrtme Pompas\u0131 (kW)<\/th>\n<th data-col-size=\"lg\">Cihaz Aray\u00fcz\u00fc (mm)<\/th>\n<th data-col-size=\"xs\">Ak\u0131\u015f (m\u00b3\/sa)<\/th>\n<th data-col-size=\"xs\">Is\u0131 \u00c7ekimi (kW)<\/th>\n<th data-col-size=\"xs\">Su Pompas\u0131 G\u00fcc\u00fc (kW)<\/th>\n<th data-col-size=\"md\">Giri\u015f\/\u00c7\u0131k\u0131\u015f (mm)<\/th>\n<th data-col-size=\"md\">Ta\u015fma (mm)<\/th>\n<th data-col-size=\"md\">At\u0131ksu Tahliye \u00c7\u0131k\u0131\u015f\u0131 (mm)<\/th>\n<th data-col-size=\"md\">Su Yenileme (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"md\">30D<\/td>\n<td data-col-size=\"sm\">174<\/td>\n<td data-col-size=\"lg\">1,5\u00d72<\/td>\n<td data-col-size=\"xl\">38,400<\/td>\n<td data-col-size=\"sm\">0.75<\/td>\n<td data-col-size=\"lg\">DN80<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN25<\/td>\n<td data-col-size=\"md\">DN25<\/td>\n<td data-col-size=\"md\">DN25<\/td>\n<td data-col-size=\"md\">DN25<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">40D<\/td>\n<td data-col-size=\"sm\">232<\/td>\n<td data-col-size=\"lg\">1,5\u00d72<\/td>\n<td data-col-size=\"xl\">51,200<\/td>\n<td data-col-size=\"sm\">1.1<\/td>\n<td data-col-size=\"lg\">DN100<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">50D<\/td>\n<td data-col-size=\"sm\">290<\/td>\n<td data-col-size=\"lg\">1,5\u00d72<\/td>\n<td data-col-size=\"xl\">64,000<\/td>\n<td data-col-size=\"sm\">1.5<\/td>\n<td data-col-size=\"lg\">DN100<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">65D<\/td>\n<td data-col-size=\"sm\">378<\/td>\n<td data-col-size=\"lg\">2.2\u00d72<\/td>\n<td data-col-size=\"xl\">83,200<\/td>\n<td data-col-size=\"sm\">1.5<\/td>\n<td data-col-size=\"lg\">DN100<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<td data-col-size=\"md\">DN32<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">80D<\/td>\n<td data-col-size=\"sm\">465<\/td>\n<td data-col-size=\"lg\">3\u00d72<\/td>\n<td data-col-size=\"xl\">102,400<\/td>\n<td data-col-size=\"sm\">2.2<\/td>\n<td data-col-size=\"lg\">DN125<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">100D<\/td>\n<td data-col-size=\"sm\">581<\/td>\n<td data-col-size=\"lg\">4\u00d72<\/td>\n<td data-col-size=\"xl\">128,000<\/td>\n<td data-col-size=\"sm\">3<\/td>\n<td data-col-size=\"lg\">DN125<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">125D<\/td>\n<td data-col-size=\"sm\">727<\/td>\n<td data-col-size=\"lg\">5,5\u00d72<\/td>\n<td data-col-size=\"xl\">160,000<\/td>\n<td data-col-size=\"sm\">3<\/td>\n<td data-col-size=\"lg\">DN150<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">150D<\/td>\n<td data-col-size=\"sm\">872<\/td>\n<td data-col-size=\"lg\">4\u00d73<\/td>\n<td data-col-size=\"xl\">192,000<\/td>\n<td data-col-size=\"sm\">4<\/td>\n<td data-col-size=\"lg\">DN150<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">180D<\/td>\n<td data-col-size=\"sm\">1,046<\/td>\n<td data-col-size=\"lg\">5.5\u00d73<\/td>\n<td data-col-size=\"xl\">240,000<\/td>\n<td data-col-size=\"sm\">4<\/td>\n<td data-col-size=\"lg\">DN125\u00d72<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">200D<\/td>\n<td data-col-size=\"sm\">1,163<\/td>\n<td data-col-size=\"lg\">4\u00d74<\/td>\n<td data-col-size=\"xl\">256,000<\/td>\n<td data-col-size=\"sm\">4<\/td>\n<td data-col-size=\"lg\">DN125\u00d72<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">225D<\/td>\n<td data-col-size=\"sm\">1,308<\/td>\n<td data-col-size=\"lg\">4\u00d74<\/td>\n<td data-col-size=\"xl\">256,000<\/td>\n<td data-col-size=\"sm\">5.5<\/td>\n<td data-col-size=\"lg\">DN150\u00d72<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\">250D<\/td>\n<td data-col-size=\"sm\">1,453<\/td>\n<td data-col-size=\"lg\">5\u00d74<\/td>\n<td data-col-size=\"xl\">320,000<\/td>\n<td data-col-size=\"sm\">5.5<\/td>\n<td data-col-size=\"lg\">DN150\u00d72<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"xs\">\u2014<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<td data-col-size=\"md\">DN40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 dir=\"auto\">Why Choose Our Closed Cooling Tower for Your Cable Production Line?<\/h3>\n<p dir=\"auto\">As a long-established supplier of complete wire and cable machinery solutions, we understand that every auxiliary component must enhance overall line reliability and productivity. This <strong>water cooling tower for cooling industrial equipments<\/strong> eliminates the downtime, high maintenance, and quality risks associated with open towers\u2014while delivering measurable cost savings in energy, water, and labor.<\/p>\n<p dir=\"auto\">Whether you run high-speed <strong>tel b\u00fckme makinesi<\/strong>, \u00e7ok ba\u015fl\u0131 <strong>demetleme makinesi<\/strong>, veya b\u00fcy\u00fck \u00e7apl\u0131 <strong>tel \u00e7ekme makinesi<\/strong> lines, our closed cooling towers provide the stable, clean cooling essential for defect-free output and long-term operational excellence.<\/p>\n<p dir=\"auto\"><strong>Ready to optimize your cable plant\u2019s cooling system?<\/strong><\/p>\n<p dir=\"auto\"><strong>\u015eimdi bilgi isteyin<\/strong>\u00a0for detailed technical proposals, layout integration support, and customized configurations tailored to your <strong>tel b\u00fckme makinesi<\/strong>, <strong>demetleme makinesi<\/strong>, Ve <strong>tel \u00e7ekme makinesi<\/strong> requirements.<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p dir=\"auto\">Kapal\u0131 Devre So\u011futma Kulelerimiz, tamamen s\u0131zd\u0131rmaz bir serpantin sistemi arac\u0131l\u0131\u011f\u0131yla kirlenme i\u00e7ermeyen, enerji a\u00e7\u0131s\u0131ndan verimli \u0131s\u0131 reddetme sa\u011flar. Kablo \u00fcretim hatlar\u0131 i\u00e7in ideal yard\u0131mc\u0131 ekipman olup, hassas s\u0131cakl\u0131k kontrol\u00fc, minimum su kullan\u0131m\u0131 ve kire\u00e7lenme veya kirlilik riski s\u0131f\u0131r olmas\u0131n\u0131 sa\u011flar.<\/p>","protected":false},"featured_media":29620,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_brand":[],"product_cat":[21,80,88],"product_tag":[1064,1063,1066,1067,1065,1068,1069],"class_list":{"0":"post-28479","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-product","7":"product_cat-cable-machinery","8":"product_cat-test-equipment","9":"product_tag-closed-circuit-cooling-tower","10":"product_tag-closed-cooling-tower","11":"product_tag-closed-loop-cooling-tower","12":"product_tag-evaporative-fluid-cooler","13":"product_tag-water-cooling-tower-for-industrial-equipments","14":"product_tag-wire-drawing-machine-cooling","15":"product_tag-wire-stranding-machine-cooling","17":"first","18":"instock","19":"shipping-taxable","20":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/comments?post=28479"}],"version-history":[{"count":5,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28479\/revisions"}],"predecessor-version":[{"id":30118,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28479\/revisions\/30118"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/media\/29620"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/media?parent=28479"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_brand?post=28479"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_cat?post=28479"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_tag?post=28479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}