{"id":28591,"date":"2026-04-26T07:13:13","date_gmt":"2026-04-26T07:13:13","guid":{"rendered":"https:\/\/doingcable.com\/?post_type=product&#038;p=28591"},"modified":"2026-08-01T07:57:34","modified_gmt":"2026-08-01T07:57:34","slug":"su-gecirmez-bant-suyla-sisen-bant","status":"publish","type":"product","link":"https:\/\/doingcable.com\/tr\/product\/su-gecirmez-bant-suyla-sisen-bant\/","title":{"rendered":"Su Tutucu Bant \/ Si\u015fen Bant"},"content":{"rendered":"<p dir=\"auto\"><strong>Su Tutucu Bant \/ Si\u015fen Bant<\/strong> is a non-woven polyester fabric impregnated with superabsorbent polymer (SAP, primarily sodium polyacrylate) that provides rapid longitudinal water blocking in power, control, and optical cables. Upon water contact it absorbs moisture and expands into a stable gel within 1\u20133 minutes, sealing interstices and limiting longitudinal migration typically to less than 1 m under standard hydrostatic test conditions.<\/p>\n<p dir=\"auto\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-30189\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables.png\" alt=\"Kablolar i\u00e7in G\u00fcvenilir Su Ge\u00e7irmez Bant\" width=\"774\" height=\"581\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables.png 2048w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-400x300.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-1067x800.png 1067w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-768x576.png 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-1536x1152.png 1536w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-16x12.png 16w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-430x323.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-700x525.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Reliable-Water-Blocking-Tape-for-Cables-250x188.png 250w\" sizes=\"(max-width: 774px) 100vw, 774px\" \/><\/p>\n<h3 dir=\"auto\">How Water Blocking \/ Swellable Tape Functions in Cable Construction<\/h3>\n<p dir=\"auto\">The tape is applied longitudinally or helically over the insulation screen, under the metallic screen\/sheath, or over armour wires. When water enters through a jacket breach, joint, or sheath defect, SAP particles absorb liquid by osmosis and hydrogen bonding. Volume expansion fills voids between conductors, screens and sheath, forming a high-viscosity gel barrier that resists further axial flow.<\/p>\n<p dir=\"auto\">Typical laboratory performance (GB\/T and manufacturer data aligned with IEC 60502 water-penetration principles):<\/p>\n<ul dir=\"auto\">\n<li>Swelling height: \u226512\u201318 mm within 1\u20133 min (single-side vs double-side grades)<\/li>\n<li>\u015ei\u015fme h\u0131z\u0131: \u0130lk dakikada \u22656\u201312 mm<\/li>\n<li>Tensile strength: \u226525\u201350 N\/cm<\/li>\n<li>Elongation: \u22658\u201314 %<\/li>\n<li>Short-term thermal stability: 230 \u00b0C (processing \/ extrusion)<\/li>\n<li>Long-term operating temperature: 90 \u00b0C<\/li>\n<li>Moisture content: \u22649 %<\/li>\n<\/ul>\n<p dir=\"auto\">Semi-conductive grades incorporate carbon black for controlled volume resistivity (typically \u22640.05\u20130.1 M\u03a9\u00b7cm surface), ensuring electrical continuity between insulation screen and metallic sheath. Non-conductive grades are used over screens or armour where insulation integrity is required.<\/p>\n<p dir=\"auto\"><img decoding=\"async\" class=\"alignnone  wp-image-28749\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624.png\" alt=\"kablo i\u00e7in su ge\u00e7irmez bant\" width=\"771\" height=\"514\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624.png 900w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624-430x287.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624-250x167.png 250w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624-700x467.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624-400x267.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/54898cd09c2362a8e16f284d361a624-768x512.png 768w\" sizes=\"(max-width: 771px) 100vw, 771px\" \/><\/p>\n<h3 dir=\"auto\">Ba\u015fl\u0131ca Teknik Avantajlar ve Performans Faydalar\u0131<\/h3>\n<p dir=\"auto\"><strong>H\u0131zl\u0131 ve Y\u00fcksek Verimli \u015ei\u015fme<\/strong> Y\u00fcksek jel mukavemeti sayesinde h\u0131zl\u0131 \u015fi\u015fme kineti\u011fi sa\u011flar ve suyun ge\u00e7i\u015fini neredeyse an\u0131nda engeller; bu da fiber optik ve g\u00fc\u00e7 kablolar\u0131nda zorlu su ge\u00e7irmezlik testlerinden ge\u00e7mek i\u00e7in kritik \u00f6neme sahiptir.<\/p>\n<p dir=\"auto\"><strong>\u0130\u015flem Dostu Mekanik \u00d6zellikler<\/strong><\/p>\n<ul dir=\"auto\">\n<li>\u00c7ekme dayan\u0131m\u0131: \u226525\u201350 N\/cm (g\u00fc\u00e7lendirilmi\u015f kalitelerde daha y\u00fcksek)<\/li>\n<li>Uzama: \u22658\u201314%<\/li>\n<li>Hafif ve ince profil (tipik olarak 0,1\u20130,3 mm)<\/li>\n<\/ul>\n<p dir=\"auto\">Bu \u00f6zellikler, y\u00fcksek h\u0131zl\u0131 hatlarda y\u0131rt\u0131lma, k\u0131r\u0131\u015fma veya toz olu\u015fumu olmadan d\u00fczg\u00fcn uzunlamas\u0131na veya sarmal uygulama sa\u011flar.<\/p>\n<p dir=\"auto\"><strong>Her Kablo Tasar\u0131m\u0131 \u0130\u00e7in \u00c7ok Y\u00f6nl\u00fc Konfig\u00fcrasyonlar<\/strong> \u015eu dillerde mevcuttur:<\/p>\n<ul dir=\"auto\">\n<li><strong>Tek tarafl\u0131<\/strong> Ve <strong>\u00e7ift tarafl\u0131<\/strong> versiyonlar<\/li>\n<li><strong>\u0130letken olmayan<\/strong> (fiber optik ve telekom kablolar\u0131 i\u00e7in standart)<\/li>\n<li><strong>Yar\u0131 iletken<\/strong> (Orta ve y\u00fcksek gerilim g\u00fc\u00e7 kablolar\u0131n\u0131n metalik ekranlar boyunca elektriksel s\u00fcreklili\u011fi sa\u011flamas\u0131 i\u00e7in gereklidir)<\/li>\n<\/ul>\n<p dir=\"auto\"><strong>M\u00fckemmel \u00c7evresel ve Termal Kararl\u0131l\u0131k<\/strong><\/p>\n<ul dir=\"auto\">\n<li>K\u0131sa vadeli kararl\u0131l\u0131k: 230\u00b0C&#039;ye kadar (ekstr\u00fczyon ve i\u015fleme s\u0131ras\u0131nda)<\/li>\n<li>Uzun s\u00fcreli \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131: 90\u00b0C&#039;ye kadar<\/li>\n<li>D\u00fc\u015f\u00fck nem i\u00e7eri\u011fi ve REACH &amp; RoHS standartlar\u0131na tam uyumluluk.<\/li>\n<\/ul>\n<p dir=\"auto\">\u00d6zel uygulamalar i\u00e7in alev geciktirici ve takviyeli kaliteler de mevcuttur.<\/p>\n<p dir=\"auto\"><strong>Uzun S\u00fcreli Jel B\u00fct\u00fcnl\u00fc\u011f\u00fc<\/strong> Olu\u015fan jel, kablonun kullan\u0131m \u00f6mr\u00fc boyunca stabil kal\u0131r ve su a\u011fa\u00e7lanmas\u0131n\u0131, iletken korozyonunu ve dielektrik bozulmas\u0131n\u0131 \u00f6nleyerek yeralt\u0131, denizalt\u0131 ve d\u0131\u015f mekan kurulumlar\u0131nda kablo g\u00fcvenilirli\u011fini \u00f6nemli \u00f6l\u00e7\u00fcde art\u0131r\u0131r.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-28750\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b.png\" alt=\"EPDM Kau\u00e7uk Havuz Astar\u0131 Nas\u0131l Birle\u015ftirilir?\" width=\"805\" height=\"427\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b.png 1100w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b-430x228.png 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b-250x133.png 250w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b-700x372.png 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b-400x212.png 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/66b8c8dbc1ab2108c9606924f4f654b-768x408.png 768w\" sizes=\"(max-width: 805px) 100vw, 805px\" \/><\/p>\n<h3 dir=\"auto\">Kablo Sistemlerinde Ba\u015fl\u0131ca Uygulamalar<\/h3>\n<p dir=\"auto\">Su ge\u00e7irmez bant, kablo \u00e7ekirde\u011fi ile d\u0131\u015f k\u0131l\u0131f aras\u0131nda boylamas\u0131na su ge\u00e7irmez katman olarak yayg\u0131n olarak a\u015fa\u011f\u0131daki uygulamalarda kullan\u0131l\u0131r:<\/p>\n<ul dir=\"auto\">\n<li><strong>Optik Fiber Kablolar<\/strong> (gev\u015fek t\u00fcp, \u015ferit, mikro kablo ve denizalt\u0131 tasar\u0131mlar\u0131)<\/li>\n<li><strong>Telekom\u00fcnikasyon ve Veri \u0130letim Kablolar\u0131<\/strong><\/li>\n<li><strong>Kontrol ve Enstr\u00fcmantasyon Kablolar\u0131<\/strong><\/li>\n<li><strong>Orta ve Y\u00fcksek Gerilim G\u00fc\u00e7 Kablolar\u0131<\/strong> (MV\/HV)<\/li>\n<li><strong>Yeralt\u0131, Do\u011frudan Topra\u011fa G\u00f6m\u00fcl\u00fc, Denizalt\u0131 ve A\u00e7\u0131k Hava Kablolar\u0131<\/strong> nem riskine maruz kalma<\/li>\n<\/ul>\n<p dir=\"auto\">\u00d6zellikle di\u011fer bariyerlerle (\u00f6rne\u011fin kopolimer kapl\u0131 bantlar veya metal k\u0131l\u0131flar) birlikte kullan\u0131ld\u0131\u011f\u0131nda, kapsaml\u0131 radyal ve boylamsal koruma i\u00e7in son derece etkilidir.<\/p>\n<p dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-30933\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable.avif\" alt=\"Water Blocking Tape Water Swellable Tape-doingcable\" width=\"638\" height=\"512\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable.avif 638w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable-374x300.avif 374w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable-15x12.avif 15w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable-430x345.avif 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Water-Blocking-Tape-Water-Swellable-Tape-doingcable-250x201.avif 250w\" sizes=\"(max-width: 638px) 100vw, 638px\" \/><\/p>\n<h4 dir=\"auto\">Su Ge\u00e7irmez Bant vs. Su Ge\u00e7irmez Toz ve \u015ei\u015febilen \u0130plik \u2013 H\u0131zl\u0131 Kar\u015f\u0131la\u015ft\u0131rma<\/h4>\n<table>\n<thead>\n<tr>\n<th data-col-size=\"md\">\u00d6zellik<\/th>\n<th data-col-size=\"lg\">Su Ge\u00e7irmez Bant<\/th>\n<th data-col-size=\"md\">Su Engelleyici Toz (SAP)<\/th>\n<th data-col-size=\"sm\">\u015ei\u015febilen \u0130plik<\/th>\n<th data-col-size=\"lg\">En \u0130yisi \u0130\u00e7in<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"md\"><strong>Uygulama Y\u00f6ntemi<\/strong><\/td>\n<td data-col-size=\"lg\">Boyuna\/sarmal sarma<\/td>\n<td data-col-size=\"md\">Karaya oturma s\u0131ras\u0131nda do\u011frudan ekleme<\/td>\n<td data-col-size=\"sm\">\u00c7ekirde\u011fe veya ba\u011flay\u0131c\u0131ya entegre edilmi\u015ftir<\/td>\n<td data-col-size=\"lg\">D\u00fczg\u00fcn da\u011f\u0131l\u0131m i\u00e7in bant<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\"><strong>\u015ei\u015fme H\u0131z\u0131<\/strong><\/td>\n<td data-col-size=\"lg\">\u00c7ok h\u0131zl\u0131 (\u226512\u201318 mm\/3 dk)<\/td>\n<td data-col-size=\"md\">An\u0131nda jel olu\u015fumu<\/td>\n<td data-col-size=\"sm\">Il\u0131man<\/td>\n<td data-col-size=\"lg\">Y\u00fcksek h\u0131zl\u0131 otomatik hatlar<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\"><strong>Mekanik Mukavemet<\/strong><\/td>\n<td data-col-size=\"lg\">Y\u00fcksek \u00e7ekme dayan\u0131m\u0131 ve uzama<\/td>\n<td data-col-size=\"md\">Yok (sadece toz)<\/td>\n<td data-col-size=\"sm\">\u0130yi (iplik takviyesi)<\/td>\n<td data-col-size=\"lg\">Yap\u0131sal b\u00fct\u00fcnl\u00fck gereklidir.<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\"><strong>\u0130letkenlik Se\u00e7enekleri<\/strong><\/td>\n<td data-col-size=\"lg\">Yar\u0131 iletken ve iletken olmayan<\/td>\n<td data-col-size=\"md\">Sadece iletken olmayan<\/td>\n<td data-col-size=\"sm\">S\u0131n\u0131rl\u0131<\/td>\n<td data-col-size=\"lg\">G\u00fc\u00e7 kablolar\u0131 (yar\u0131 iletken)<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\"><strong>Temizlik ve Toz<\/strong><\/td>\n<td data-col-size=\"lg\">\u00c7ok temiz<\/td>\n<td data-col-size=\"md\">Ta\u015f\u0131ma s\u0131ras\u0131nda olu\u015fabilecek toz<\/td>\n<td data-col-size=\"sm\">Temiz<\/td>\n<td data-col-size=\"lg\">Modern y\u00fcksek h\u0131zl\u0131 \u00fcretim<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"md\"><strong>Tipik Kullan\u0131m<\/strong><\/td>\n<td data-col-size=\"lg\">Fiber optik, telekom\u00fcnikasyon, orta\/y\u00fcksek gerilim enerji<\/td>\n<td data-col-size=\"md\">\u0130letken b\u00fck\u00fclmesi<\/td>\n<td data-col-size=\"sm\">Hafif fiber optik \u00e7ekirdekler<\/td>\n<td data-col-size=\"lg\">\u00c7ok y\u00f6nl\u00fc uzunlamas\u0131na bloklama<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"auto\">Bu kar\u015f\u0131la\u015ft\u0131rma, bir\u00e7ok \u00fcreticinin karma\u015f\u0131k kablo yap\u0131lar\u0131nda performans, kullan\u0131m kolayl\u0131\u011f\u0131 ve g\u00fcvenilirlik dengesi nedeniyle Su Ge\u00e7irmez Band\u0131 tercih etmesinin nedenini g\u00f6stermektedir.<\/p>\n<p dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-30935\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable.webp\" alt=\"Tapes for power cable-doingcable\" width=\"1133\" height=\"615\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable.webp 2000w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-400x217.webp 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-1300x706.webp 1300w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-768x417.webp 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-1536x834.webp 1536w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-18x10.webp 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-430x233.webp 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-700x380.webp 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Tapes-for-power-cable-doingcable-250x136.webp 250w\" sizes=\"(max-width: 1133px) 100vw, 1133px\" \/><\/p>\n<h3 dir=\"auto\">Teknik \u00d6zellikler<\/h3>\n<h4>Yar\u0131 \u0130letken Su Ge\u00e7irmez Bant (Tek Tarafl\u0131)<\/h4>\n<table>\n<thead>\n<tr>\n<th data-col-size=\"lg\">Thickness (mm)<\/th>\n<th data-col-size=\"lg\">Mass per Area (g\/m\u00b2)<\/th>\n<th data-col-size=\"sm\">Tensile Strength (N\/cm)<\/th>\n<th data-col-size=\"sm\">Elongation (%)<\/th>\n<th data-col-size=\"sm\">Swelling Speed (mm\/1 min)<\/th>\n<th data-col-size=\"sm\">Swelling Height (mm\/3 min)<\/th>\n<th data-col-size=\"md\">Surface Resistance (\u03a9)<\/th>\n<th data-col-size=\"lg\">Volume Resistance (\u03a9\u00b7cm)<\/th>\n<th data-col-size=\"xs\">Moisture Content (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"lg\">0.25 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">90 \u00b1 5<\/td>\n<td data-col-size=\"sm\">\u226525<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u22656<\/td>\n<td data-col-size=\"sm\">\u22658<\/td>\n<td data-col-size=\"md\">\u22641500<\/td>\n<td data-col-size=\"lg\">&lt;1\u00d710\u2076<\/td>\n<td data-col-size=\"xs\">\u22649<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.30 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">100 \u00b1 5<\/td>\n<td data-col-size=\"sm\">\u226530<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u22658<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"md\">\u22641500<\/td>\n<td data-col-size=\"lg\">&lt;1\u00d710\u2076<\/td>\n<td data-col-size=\"xs\">\u22649<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.35 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">110 \u00b1 5<\/td>\n<td data-col-size=\"sm\">\u226535<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u226510<\/td>\n<td data-col-size=\"sm\">\u226514<\/td>\n<td data-col-size=\"md\">\u22641500<\/td>\n<td data-col-size=\"lg\">&lt;1\u00d710\u2076<\/td>\n<td data-col-size=\"xs\">\u22649<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.40 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">130 \u00b1 10<\/td>\n<td data-col-size=\"sm\">\u226540<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u226511<\/td>\n<td data-col-size=\"sm\">\u226515<\/td>\n<td data-col-size=\"md\">\u22641500<\/td>\n<td data-col-size=\"lg\">&lt;1\u00d710\u2076<\/td>\n<td data-col-size=\"xs\">\u22649<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.50 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">160 \u00b1 10<\/td>\n<td data-col-size=\"sm\">\u226550<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u226518<\/td>\n<td data-col-size=\"md\">\u22641500<\/td>\n<td data-col-size=\"lg\">&lt;1\u00d710\u2076<\/td>\n<td data-col-size=\"xs\">\u22649<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h4 dir=\"auto\">\u0130letken Olmayan Su Ge\u00e7irmez Bant (\u00c7ift Tarafl\u0131 \u00d6rnek)<\/h4>\n<table>\n<thead>\n<tr>\n<th data-col-size=\"lg\">Thickness (mm)<\/th>\n<th data-col-size=\"lg\">Mass per Area (g\/m\u00b2)<\/th>\n<th data-col-size=\"sm\">Tensile Strength (N\/cm)<\/th>\n<th data-col-size=\"sm\">Elongation (%)<\/th>\n<th data-col-size=\"sm\">Swelling Speed (mm\/1 min)<\/th>\n<th data-col-size=\"sm\">Swelling Height (mm\/3 min)<\/th>\n<th data-col-size=\"xs\">Moisture Content (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"lg\">0.18 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">65 \u00b1 10<\/td>\n<td data-col-size=\"sm\">\u226525<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u22654<\/td>\n<td data-col-size=\"sm\">\u22656<\/td>\n<td data-col-size=\"xs\">\u22646<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.25 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">80 \u00b1 10<\/td>\n<td data-col-size=\"sm\">\u226530<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u22658<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"xs\">\u22646<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">0.30 \u00b1 0.03<\/td>\n<td data-col-size=\"lg\">90 \u00b1 10<\/td>\n<td data-col-size=\"sm\">\u226535<\/td>\n<td data-col-size=\"sm\">\u226512<\/td>\n<td data-col-size=\"sm\">\u226510<\/td>\n<td data-col-size=\"sm\">\u226514<\/td>\n<td data-col-size=\"xs\">\u22646<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"auto\"><strong>Not<\/strong>Tek tarafl\u0131 ve \u00e7ift tarafl\u0131, iletken ve iletken olmayan t\u00fcm \u00fcr\u00fcn \u00e7e\u015fitleri mevcuttur. \u0130stek \u00fczerine \u00f6zel \u00f6zellikler de sa\u011flanabilir.<\/p>\n<table>\n<thead>\n<tr>\n<th data-col-size=\"lg\">Parametre<\/th>\n<th data-col-size=\"md\">Yar\u0131 \u0130letken (Tek Tarafl\u0131)<\/th>\n<th data-col-size=\"md\">\u0130letken Olmayan (\u00c7ift Tarafl\u0131)<\/th>\n<th data-col-size=\"lg\">Test Ko\u015fulu \/ Standard\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"lg\">\u015ei\u015flik Y\u00fcksekli\u011fi<\/td>\n<td data-col-size=\"md\">\u226512 mm<\/td>\n<td data-col-size=\"md\">\u226518 mm<\/td>\n<td data-col-size=\"lg\">1-3 dakika i\u00e7inde<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u015ei\u015fme H\u0131z\u0131<\/td>\n<td data-col-size=\"md\">H\u0131zl\u0131<\/td>\n<td data-col-size=\"md\">\u00c7ok h\u0131zl\u0131<\/td>\n<td data-col-size=\"lg\">Suyla temas etti\u011finde<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u00c7ekme Mukavemeti<\/td>\n<td data-col-size=\"md\">Y\u00fcksek<\/td>\n<td data-col-size=\"md\">Y\u00fcksek<\/td>\n<td data-col-size=\"lg\">Karaya oturma s\u0131ras\u0131nda<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131 (K\u0131sa S\u00fcreli)<\/td>\n<td data-col-size=\"md\">230\u00b0C&#039;ye kadar<\/td>\n<td data-col-size=\"md\">230\u00b0C&#039;ye kadar<\/td>\n<td data-col-size=\"lg\">\u0130\u015fleme kararl\u0131l\u0131\u011f\u0131<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131 (Uzun S\u00fcreli)<\/td>\n<td data-col-size=\"md\">90\u00b0C&#039;ye kadar<\/td>\n<td data-col-size=\"md\">90\u00b0C&#039;ye kadar<\/td>\n<td data-col-size=\"lg\">Hizmet \u00f6mr\u00fc<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Nem \u0130\u00e7eri\u011fi<\/td>\n<td data-col-size=\"md\">D\u00fc\u015f\u00fck<\/td>\n<td data-col-size=\"md\">D\u00fc\u015f\u00fck<\/td>\n<td data-col-size=\"lg\">\u00dcretim \u00f6ncesi<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"lg\">Uyumluluk<\/td>\n<td data-col-size=\"md\">REACH ve RoHS<\/td>\n<td data-col-size=\"md\">REACH ve RoHS<\/td>\n<td data-col-size=\"lg\">\u00c7evre standartlar\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"auto\">(Tam kablo tasar\u0131mlar\u0131na uygun \u00f6zel tek tarafl\u0131 \/ \u00e7ift tarafl\u0131, iletken \/ iletken olmayan kaliteler mevcuttur.)<\/p>\n<p dir=\"auto\">\n<p dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-30934\" src=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable.jpg\" alt=\"Conductive vs Non-Conductive Grades-doingcable\" width=\"1024\" height=\"559\" srcset=\"https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable.jpg 1024w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-400x218.jpg 400w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-768x419.jpg 768w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-18x10.jpg 18w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-430x235.jpg 430w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-700x382.jpg 700w, https:\/\/doingcable.com\/wp-content\/uploads\/2026\/04\/Conductive-vs-Non-Conductive-Grades-doingcable-250x136.jpg 250w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h3 dir=\"auto\">Key Technical Parameters Summary<\/h3>\n<table>\n<thead>\n<tr>\n<th data-col-size=\"xl\">Grade Type<\/th>\n<th data-col-size=\"lg\">Thickness (mm)<\/th>\n<th data-col-size=\"md\">Mass (g\/m\u00b2)<\/th>\n<th data-col-size=\"sm\">Swelling Speed (mm\/1 min)<\/th>\n<th data-col-size=\"md\">Swelling Height (mm\/3 min)<\/th>\n<th data-col-size=\"md\">Tensile (N\/cm)<\/th>\n<th data-col-size=\"xs\">Short-term Stability (\u00b0C)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-col-size=\"xl\">Non-cond. thin<\/td>\n<td data-col-size=\"lg\">0.20 \u00b1 0.03<\/td>\n<td data-col-size=\"md\">70\u201380<\/td>\n<td data-col-size=\"sm\">\u22656\u20139<\/td>\n<td data-col-size=\"md\">\u22659\u201312<\/td>\n<td data-col-size=\"md\">\u226525\u201335<\/td>\n<td data-col-size=\"xs\">230<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"xl\">Non-cond. standard<\/td>\n<td data-col-size=\"lg\">0.25\u20130.30<\/td>\n<td data-col-size=\"md\">85\u2013110<\/td>\n<td data-col-size=\"sm\">\u22658\u201312<\/td>\n<td data-col-size=\"md\">\u226512\u201316<\/td>\n<td data-col-size=\"md\">\u226535\u201350<\/td>\n<td data-col-size=\"xs\">230<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"xl\">Semi-cond. standard<\/td>\n<td data-col-size=\"lg\">0.30 \u00b1 0.02<\/td>\n<td data-col-size=\"md\">120\u2013125<\/td>\n<td data-col-size=\"sm\">\u22658\u201312<\/td>\n<td data-col-size=\"md\">\u226512\u201316<\/td>\n<td data-col-size=\"md\">\u226550\u201353<\/td>\n<td data-col-size=\"xs\">230<\/td>\n<\/tr>\n<tr>\n<td data-col-size=\"xl\">High-swell reinforced<\/td>\n<td data-col-size=\"lg\">0.40\u20130.50<\/td>\n<td data-col-size=\"md\">120\u2013140<\/td>\n<td data-col-size=\"sm\">\u226510\u201312<\/td>\n<td data-col-size=\"md\">\u226515\u201318<\/td>\n<td data-col-size=\"md\">\u226540<\/td>\n<td data-col-size=\"xs\">230\u2013250<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 dir=\"auto\">Standards, Testing and Recent Industry Requirements<\/h3>\n<p dir=\"auto\">IEC 60502 series defines water-penetration tests (longitudinal, with 1 m water head and thermal cycles). IEEE 3150-2025 (published August 2025) specifically addresses testing methods for semi-conductive water-blocking tape in 110\u2013500 kV XLPE AC cables, focusing on properties that prevent buffer-layer ablation failures. Chinese industry standard YD\/T 1115.1-2023 covers telecommunications and optical-fibre applications. REACH &amp; RoHS compliance is mandatory for global supply.<\/p>\n<p dir=\"auto\">Recent field experience (2020\u20132026) shows that incomplete drying or excessive moisture content in the tape before sheathing can lead to white powder precipitation (sodium polyacrylate + aluminium corrosion products). This raises volume resistivity, lowers relative permittivity and thermal conductivity, and can initiate partial discharge between the tape and aluminium sheath\u2014resulting in local ablation of the buffer layer. Proper moisture control (&lt;9 %), correct overlap, and verified swelling performance after heat ageing (90 \u00b0C, 12 months equivalent) are therefore critical process controls.<\/p>\n<h3 dir=\"auto\">Application Guidelines and Process Considerations<\/h3>\n<ul dir=\"auto\">\n<li><strong>Medium- and high-voltage XLPE power cables<\/strong>: Semi-conductive tape applied over insulation screen, under metallic sheath; optional second non-conductive layer over wire screen.<\/li>\n<li><strong>Submarine \/ wet-location cables<\/strong>: Double-side high-swell grades combined with radial moisture barriers (Al\/PE laminate).<\/li>\n<li><strong>Optical fibre and hybrid cables<\/strong>: Thin non-conductive tape or yarn for interstitial filling.<\/li>\n<li><strong>\u0130\u015fleniyor<\/strong>: Tape must withstand CV-line temperatures up to 230 \u00b0C without powder loss or dimensional change. Widths are slit from 8 mm to &gt;500 mm; core diameters typically 76\u2013150 mm.<\/li>\n<\/ul>\n<p dir=\"auto\">Common failure modes to avoid:<\/p>\n<ol dir=\"auto\">\n<li>Insufficient swelling height after ageing \u2192 incomplete sealing under pressure.<\/li>\n<li>High residual moisture \u2192 premature gelation or powder migration.<\/li>\n<li>Incorrect conductivity grade \u2192 equipotential disruption or dielectric stress.<\/li>\n<li>Mechanical damage during high-speed application \u2192 gaps that allow water tracking.<\/li>\n<\/ol>\n<h3 dir=\"auto\">Practical Recommendations for Cable Manufacturers and Specifiers<\/h3>\n<p dir=\"auto\">Specify tape by measured swelling performance after thermal ageing rather than nominal thickness alone. Verify volume resistivity and surface conductivity for semi-conductive grades under the conditions defined in IEEE 3150-2025. Maintain low incoming moisture and control application tension to avoid wrinkles or gaps. For critical HV circuits, combine longitudinal swellable tape with a continuous radial metallic or laminated moisture barrier.<\/p>\n<p dir=\"auto\">Water Blocking \/ Swellable Tape remains the most process-compatible and cost-effective solution for reliable longitudinal water blocking in modern XLPE, EPR and optical cable constructions. Proper grade selection and process control directly extend service life and reduce repair costs caused by moisture-induced failures.<\/p>\n<p dir=\"auto\"><strong>\u015eimdi bilgi isteyin<\/strong> for detailed technical data sheets, custom slit widths, swelling test reports, or sample evaluation for your specific cable designs.<\/p>","protected":false},"excerpt":{"rendered":"<p dir=\"auto\">S\u00fcper emici polimer (SAP) emdirilmi\u015f y\u00fcksek mukavemetli polyester nonwoven (dokusuz) kuma\u015ftan \u00fcretilen profesyonel s\u0131n\u0131f Su Durdurucu Bant (Su \u015ei\u015fen Bant olarak da bilinir). Fiber optik, enerji, telekom\u00fcnikasyon ve kontrol kablolar\u0131nda uzunlamas\u0131na su s\u0131z\u0131nt\u0131s\u0131n\u0131 durduran yo\u011fun, kararl\u0131 bir jel bariyer olu\u015fturmak i\u00e7in suyla temas etti\u011finde h\u0131zla \u015fi\u015fer. \u0130letken olmayan ve yar\u0131 iletken derecelerde, tek tarafl\u0131 veya \u00e7ift tarafl\u0131 konfig\u00fcrasyonlarda mevcuttur. Y\u00fcksek h\u0131zl\u0131 kablo \u00fcretim hatlar\u0131 i\u00e7in \u00f6zel geni\u015flikler, gramajlar ve performans parametreleri desteklenir.<\/p>","protected":false},"featured_media":29455,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_brand":[],"product_cat":[21,93,91],"product_tag":[199,234,235,233,231,232],"class_list":{"0":"post-28591","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-product","7":"product_cat-auxiliary-material-for-cable","8":"product_cat-cable-material","9":"product_tag-longitudinal-water-blocking","10":"product_tag-optical-fiber-cable-tape","11":"product_tag-power-cable-water-blocking","12":"product_tag-sap-cable-tape","13":"product_tag-water-blocking-tape","14":"product_tag-water-swellable-tape","16":"first","17":"instock","18":"shipping-taxable","19":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28591","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/comments?post=28591"}],"version-history":[{"count":6,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28591\/revisions"}],"predecessor-version":[{"id":30936,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product\/28591\/revisions\/30936"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/media\/29455"}],"wp:attachment":[{"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/media?parent=28591"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_brand?post=28591"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_cat?post=28591"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/doingcable.com\/tr\/wp-json\/wp\/v2\/product_tag?post=28591"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}